Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
J Med Virol ; 95(4): e28703, 2023 04.
Article in English | MEDLINE | ID: covidwho-2288875

ABSTRACT

Given the prevalence of low-pathogenic but highly infectious Omicron variants, a cohort study was conducted to assess the response and duration of novel coronavirus-inactivated vaccine-induced antibodies 1 year after the third dose (Day 641). Blood samples were collected and anti-spike neutralizing antibodies (neutralizing antibody), total antibodies against the receptor-binding domain of the spike protein (total antibody), and immunoglobulin G antibodies against the spike protein (IgG antibody) were determined. Antibody kinetics and attenuation were evaluated. The results showed that the levels of neutralizing, total, and IgG antibodies on Day 641 were 98.05 IU/mL, 152.8 AU/mL, and 7.68 S/CO, respectively. Levels of anti-SARS-CoV-2 antibodies were higher in the younger subgroup than in the older subgroup at several time points after the second and third doses. The seropositive rate of neutralizing antibodies providing protection from infection or severe infection was 46.87% and 87.5%, and the seropositive rates of total antibody and IgG antibody were maintained at 100% and 90.63%, respectively. The half-lives of neutralizing, total, and IgG antibodies were 186.89, 363.04, and 417.50 days, respectively. Collectively, anti-SARS-CoV-2 antibodies may provide a certain degree of protection from infection 1 year after the third dose and high protection from severe infection.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Humans , Prospective Studies , Cohort Studies , Longitudinal Studies , COVID-19/prevention & control , SARS-CoV-2 , Antibodies, Viral , Antibodies, Neutralizing , Immunoglobulin G
2.
Vaccines (Basel) ; 11(2)2023 Feb 06.
Article in English | MEDLINE | ID: covidwho-2237600

ABSTRACT

To identify false-positive SARS-CoV-2 test results caused by novel coronavirus inactivated vaccine contamination, a novel RT-qPCR targeting the ORF1ab and N genes of SARS-CoV-2 and Vero gene was developed. The amplification efficiency, precision, and lower limit of detection (LLOD) of the RT-qPCR assay were determined. A total of 346 clinical samples and 132 environmental samples were assessed, and the diagnostic performance was evaluated. The results showed that the amplification efficiency of the ORF1ab, N, and Vero genes was 95%, 97%, and 93%, respectively. The coefficients of variation of Ct values at a concentration of 3 × 104 copies/mL were lower than 5%. The LLOD for the ORF1ab, N, and Vero genes reached 8.0, 3.3, and 8.2 copies/reaction, respectively. For the 346 clinical samples, our RT-qPCR assay identified SARS-CoV-2-positive and SARS-CoV-2-negative samples with a sensitivity of 100.00% and a specificity of 99.30% and novel coronavirus inactivated vaccine-contaminated samples with a sensitivity of 100% and a specificity of 100%. For the environmental samples, our RT-qPCR assay identified novel coronavirus inactivated vaccine-contaminated samples with a sensitivity of 88.06% and a specificity of 95.38%. In conclusion, the RT-qPCR assay we established can be used to diagnose COVID-19 and, to a certain extent, false-positive results due to vaccine contamination.

4.
Vaccines (Basel) ; 11(1)2023 Jan 16.
Article in English | MEDLINE | ID: covidwho-2200956

ABSTRACT

To obtain more insight into IgM in anti-SARS-CoV-2 immunity a prospective cohort study was carried out in 32 volunteers to longitudinally profile the kinetics of the anti-SARS-CoV-2 IgM response induced by administration of a three-dose inactivated SARS-CoV-2 vaccine regimen at 19 serial time points over 456 days. The first and second doses were considered primary immunization, while the third dose was considered secondary immunization. IgM antibodies showed a low secondary response that was different from the other three antibodies (neutralizing, total, and IgG antibodies). There were 31.25% (10/32) (95% CI, 14.30-48.20%) of participants who never achieved a positive IgM antibody conversion over 456 days after vaccination. The seropositivity rate of IgM antibodies was 68.75% (22/32) (95% CI, 51.80-85.70%) after primary immunization. Unexpectedly, after secondary immunization the seropositivity response rate was only 9.38% (3/32) (95% CI, 1.30-20.10%), which was much lower than that after primary immunization (p = 0.000). Spearman's correlation analysis indicated a poor correlation of IgM antibodies with the other three antibodies. IgM response in vaccinees was completely different from the response patterns of neutralizing, total, and IgG antibodies following both the primary immunization and the secondary immunization and was suppressed by pre-existing immunity induced by primary immunization.

5.
J Infect Public Health ; 15(12): 1494-1496, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2120008

ABSTRACT

To evaluate the application of cycle threshold (Ct) values of coronavirus disease 2019 (COVID-19) patients in predicting epidemic dynamics and monitoring surface contamination. The Ct value of reverse transcriptase-polymerase chain reaction for SARS­CoV-2 from COVID-19 patients inbound overseas in Xiamen, China was collected from October 2020 to December 2021, and the correlation of patients' Ct values with epidemic dynamics and surface contamination was evaluated. The results showed that there was an extreme inverse correlation of positivity rate in the current calendar month (ORF1ab, r = -0.692, P = 0.004; N,r = -0.629, P = 0.012) and the following calendar month (ORF1ab,r = -0.801, P = 0.001; N,r = -0.620, P = 0.018) with the median Ct values. Ct value showed better performance for monitoring surface contamination, with the area under the curve value 0.808(95 %CI: 0.748-0.869) for ORF1ab and 0.807(95 %CI:0.746-0.868) for the N gene. The patients' ORF1ab Ct value< 29.09 or N Ct value< 28.03 were 11.25 times and 10.48 times more likely to result in surface contamination than those with ORF1ab Ct value ≥ 29.09 or N Ct value≥ 28.03 (OR:11.25,95 % CI: 5.52-22.35; OR:10.48,95 % CI:5.29-20.70). Ct values were associated with the positivity rate in the current or following calendar month and predicted the epidemic dynamics. The Ct values can be used as a predictor for monitoring surface contamination to develop public health responses to COVID-19.


Subject(s)
COVID-19 , Epidemics , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Reverse Transcriptase Polymerase Chain Reaction , Public Health
6.
Int Immunopharmacol ; 112: 109285, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2105146

ABSTRACT

PURPOSE: The accuracy of level of anti- severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies is a great concern. We aimed to compare the efficacy of anti-SARS-CoV-2 antibody detection kits from two manufacturers in evaluating the efficacy of SARS-CoV-2 vaccines. METHODS: The immune responses and consistency of four anti-SARS-CoV-2 antibodies were evaluated using two manufacturers' antibody kits (A and B) in 61 subjects within 160 days after vaccination with the CoronaVac vaccine. RESULTS: The total seropositivity rates of neutralizing antibodies and IgM antibodies detected by kit A were higher than those detected by kit B (P = 0.003 and P < 0.001, respectively). Conversely, the total seropositivity rates of total antibodies and IgG antibodies were higher in kit B than kit A (P < 0.001 and P < 0.001, respectively). The consistency rates showed less than 90% agreement between the kits for the detection of the four antibodies, and the κ score showed moderate or substantial consistency. The half-lives of neutralizing antibodies, total antibodies, and IgG antibodies within 160 days after vaccination, detected by kit A were 63.88 days, 80.50 days, and 63.70 days, respectively and by kit B were 97.06 days, 65.41 days, and 77.99 days, respectively. CONCLUSION: The efficacy of antibody detection differed between the two commercial anti-SARS-CoV-2 antibody kits, although there was moderate consistency, which may affect the clinical application and formulation of the vaccine strategy.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Cohort Studies , Prospective Studies , COVID-19 Vaccines , COVID-19/prevention & control , Antibodies, Viral , Immunoglobulin M , Immunoglobulin G , Vaccination , Antibodies, Neutralizing
7.
Clin Chim Acta ; 532: 89-94, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1966415

ABSTRACT

BACKGROUND: Determining what quarantine period and detection strategy are more effective and sustainable remains a challenge for further prevention and social stability. METHODS: From October 2020 to December 2021, 290,547 inbound overseas travelers were subject to government quarantine in Xiamen, China. The detection rate of COVID-19 during different quarantine periods using dual or single nucleic acid testing reagents. RESULTS: The COVID-19 positive rate was 1.79% (519/290,547). The detection rates during the 7-day, 14-day and 14+7-day quarantine periods using the dual reagents were 78.4%, 91.7%, and 100%, respectively. The detection rate of the 7-day, 14-day and 14+7-day quarantine periods were 73.99%, 86.51%, and 94.22%, respectively, using the Liferiver reagent and 72.25%, 84.59%, and 91.91%, respectively, using the Daan reagent. Based on the 14+7 day strategy, dual nucleic acid testing reagent strategy detected all imported cases, but 30 cases (5.78%) were not detected via Liferiver reagent and 42 (8.09%) cases not detected via Daan reagent. CONCLUSION: A 14+7-day quarantine period and dual nucleic acid testing reagent strategy are effective screening methods for COVID-19 among inbound overseas travelers. The superior detection rate of these strategies reduce the risk of secondary transmission of the SARS-CoV-2 virus.


Subject(s)
COVID-19 , Nucleic Acids , COVID-19/diagnosis , China , Humans , Indicators and Reagents , Quarantine , SARS-CoV-2
8.
Front Med (Lausanne) ; 9: 847407, 2022.
Article in English | MEDLINE | ID: covidwho-1911056

ABSTRACT

Real-time reverse transcription-polymerase chain reaction (RT-PCR) is the gold standard for diagnosing coronavirus disease 2019 (COVID-19). However, RT-PCR may yield false-positive results, leading to unnecessary countermeasures. Here, we report a "positive" nucleic acid test on a 10-pooled sample during the routine screening that caused many adverse societal effects, and financial and resource losses. However, they were subsequently determined to be a case of vaccine contamination. This case study increases awareness of false-positive RT-PCR results for SARS-CoV-2, especially when participants are vaccinators. Moreover, it could provide relevant suggestions to prevent the recurrence of such incidents.

10.
Front Immunol ; 13: 876037, 2022.
Article in English | MEDLINE | ID: covidwho-1847175

ABSTRACT

Background: Due to anti-SARS-CoV-2 antibody decay and SARS-CoV-2 variants, vaccine booster doses are a constant concern. It was focused on whether the third dose can quickly evoke and activate immunity and produce a sufficient and durable immune protection. Objectives: To evaluate the responses and durations of five subsets of anti-SARS-CoV-2 antibodies and their predictive values for protection after the administration of a three-dose inactivated SARS-CoV-2 vaccines regimens. Methods: A prospective cohort study of five subsets of anti-SARS-CoV-2 antibodies (neutralizing antibody, anti-RBD total antibody, anti-Spike IgG, anti-Spike IgM, and anti-Spike IgA) was carried out to evaluate the efficacies and immune characteristics of a three-dose inactivated SARS-CoV-2 vaccines regimen in 32 volunteers. The dynamic response and immune decay were longitudinally profiled at 18 serial time points over 368 days. Results: The neutralizing antibody, anti-RBD total antibody, anti-Spike IgG and anti-Spike IgA levels rapidly increased to 773.60 (380.90-1273.00) IU/mL, 639.30 (399.60-878.60) AU/mL, 34.48 (16.83-44.68) S/CO and 0.91 (0.35-1.14) S/CO, respectively, after the administration of the third dose. Compared to the peak value after the second dose, these values were increased by 4.22-fold, 3.71-fold, 1.01-fold and 0.92-fold. On the other hand, the half-lives of the neutralizing antibody, anti-RBD total antibody, and anti-Spike IgG were 56.26 (95% CI, 46.81 to 70.49) days, 66.37 (95% CI, 54.90 to 83.88) days, and 82.91 (95% CI, 63.65 to 118.89) days, respectively. Compared to the half-lives after the second dose, these values were increased by 1.71-fold, 2.00-fold, and 2.93-fold, respectively. Nevertheless, the positive conversion rate of anti-Spike IgM was decreased to 9.38% (3/32), which was much lower than that after the second dose (65.63% (21/32)). Conclusions: Compared to the second dose, the third dose dramatically increased the antibody levels and decay times. However, the half-life of neutralizing antibody remained unsatisfactory. Due to decay, a fourth dose, and even annual revaccination, might be considered in the SARS-CoV-2 vaccination management strategy.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , Cohort Studies , Humans , Immunoglobulin A , Immunoglobulin G , Immunoglobulin M , Prospective Studies , Vaccines, Inactivated
11.
Frontiers in immunology ; 12, 2021.
Article in English | EuropePMC | ID: covidwho-1610580

ABSTRACT

Background A vaccine against coronavirus disease 2019 (COVID-19) with highly effective protection is urgently needed. The anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody response and duration after vaccination are crucial predictive indicators. Objectives To evaluate the response and duration for 5 subsets of anti-SARS-CoV-2 antibodies after vaccination and their predictive value for protection. Methods We determined the response and duration for 5 subsets of anti-SARS-CoV-2 antibodies (neutralizing antibody, anti-RBD total antibody, anti-Spike IgG, anti-Spike IgM, and anti-Spike IgA) in 61 volunteers within 160 days after the CoronaVac vaccine. A logistic regression model was used to determine the predictors of the persistence of neutralizing antibody persistence. Results The seropositivity rates of neutralizing antibody, anti-RBD total antibody, anti-Spike IgG, anti-Spike IgM, and anti-Spike IgA were only 4.92%, 27.87%, 21.31%, 3.28% and 0.00%, respectively, at the end of the first dose (28 days). After the second dose, the seropositivity rates reached peaks of 95.08%, 100.00%, 100.00%, 59.02% and 31.15% in two weeks (42 days). Their decay was obvious and the seropositivity rate remained at 19.67%, 54.10%, 50.82%, 3.28% and 0.00% on day 160, respectively. The level of neutralizing antibody reached a peak of 149.40 (101.00–244.60) IU/mL two weeks after the second dose (42 days) and dropped to 14.23 (7.62–30.73) IU/mL at 160 days, with a half-life of 35.61(95% CI, 32.68 to 39.12) days. Younger participants (≤31 years) had 6.179 times more persistent neutralizing antibodies than older participants (>31 years) (P<0.05). Participants with anti-Spike IgA seropositivity had 4.314 times greater persistence of neutralizing antibodies than participants without anti-Spike IgA seroconversion (P<0.05). Conclusions Antibody response for the CoronaVac vaccine was intense and comprehensive with 95.08% neutralizing seropositivity rate, while decay was also obvious after 160 days. Therefore, booster doses should be considered in the vaccine strategies.

SELECTION OF CITATIONS
SEARCH DETAIL